SHORT-CHAIN CARBOXYLIC ACID
WATER INSIGHTS
Enjoying water.
Clear answers.
Good decisions begin with your water, your questions and information you can understand.
Reducing PFAS: the filter study in charts →FILTER TECHNOLOGIES COMPARED
What can each technology do?
Compare the methods – and the combination of sediment filtration, activated carbon and reverse osmosis in AURORA and BlueVital.
AURORA and BlueVital combine sediment filtration, activated carbon and reverse osmosis. Their shared column represents how these components work together – and AQUA HELVETICA's qualitative assessment.
Qualitative assessment by AQUA HELVETICA. The terms describe an assessment of reduction performance; they are not percentages.
- NO
- LIMITED
- PARTLY
- HIGH
- VERY HIGH
On smaller screens, scroll sideways to see the full table.
| Substances in water | AURORA and BlueVitalSystems by AQUA HELVETICA | IonisationNO PURIFICATION | Filter jugs | Activated carbonGranular carbon (GAC) | Activated carbonblock filter | Distillation | Reverse osmosisSystem with pre-filtration |
|---|---|---|---|---|---|---|---|
| Limescale | VERY HIGH | ||||||
| Bacteria | VERY HIGH | ||||||
| Heavy metals | VERY HIGH | ||||||
| Chlorine | VERY HIGH | ||||||
| Pesticides | VERY HIGH | ||||||
| Pharmaceutical residues | VERY HIGH | ||||||
| Organic compounds | VERY HIGH | ||||||
| Asbestos | VERY HIGH | ||||||
| PFAS | VERY HIGH | ||||||
| TFA | VERY HIGH† | ||||||
| Microplastics (> 1 µm) | VERY HIGH | ||||||
| Nanoplastics (< 1 µm) | VERY HIGH† | ||||||
| Nitrate & nitrite | VERY HIGH | ||||||
| VOCs (solvents) | VERY HIGH |
The ratings come from the AQUA HELVETICA comparison table. Actual reduction depends on the individual substance, the components, their capacity and operating conditions. “Very high” does not mean complete removal of every substance in a group.
† The ratings for TFA and nanoplastics reflect AQUA HELVETICA's qualitative assessment. They are not based here on published test reports for these specific appliances.
DISTINCTLY SWISS – THOUGHTFULLY DESIGNED
AURORA.
Working together makes the difference.
High-quality activated carbon and sediment filtration provide pre-treatment. The reverse osmosis membrane adds the reduction of numerous dissolved substances. AURORA brings the strengths of both methods together in two carefully matched filter stages.
Activated carbon reduces free chlorine, for example, and adsorbs many organic compounds. The membrane performs further tasks. What matters is the complete system – from the pre-filter and pump to the membrane.
Discover how AURORA's technology works together →Context and sources for the comparison
Basis of the table: the “Reinigungstechnologien V2” overview supplied by AQUA HELVETICA. Its qualitative ratings are presented here as the supplier's assessment, not as independent comparative measurements.
- Reverse osmosis and pre-filtration: The reverse osmosis information refers to a system with suitable pre-filtration. In particular, chlorine reduction is achieved through pre-treatment, usually activated carbon; it is not a function of the reverse osmosis membrane alone.
- The shared column for AURORA and BlueVital describes the combination of sediment filtration, activated carbon and reverse osmosis. Both systems use this technological principle; their components and features differ. An assessment of the overall system must be distinguished from an assessment of a single method.
- * Bacteria and activated carbon block filters: Retention depends on pore size and the specific filter design. The hygiene of the complete installation also depends on use and maintenance.
- Substance groups and filter types include different variants. For example, some filter jugs with suitable media can also reduce certain PFAS. “PARTLY” describes a reduction that depends on the substance and filter; it does not replace testing of the specific product. Within the PFAS group, PFOA, PFOS and TFA behave differently.
Further background on the methods and substance-specific testing:
- EPA: activated carbon, ion exchange and membrane processes
- NSF: substance-specific testing of different filter types
- Scheurer et al. (2017): TFA and treatment methods
- DuPont: membrane performance and protection from free chlorine (PDF)
These sources explain the methods. They do not confirm every table rating or constitute certification of AURORA or BlueVital.
REDUCING PFAS · RESEARCH IN EVERYDAY LIFE
What remains in the water?
Filter technology makes the difference.
Reverse osmosis can significantly reduce PFAS contamination in drinking water. A study in occupied homes shows differences between filter technologies.
LONG-CHAIN CARBOXYLIC ACID
PFOA
LONG-CHAIN SULFONIC ACID
PFOS
The PFOA figure describes the RO group studied. Removal above 99% is also consistent with “>92%”. The figures “>92%” and “>99%” alone therefore do not establish a ranking.
RO here means complete reverse osmosis systems, including any pre-filters. The percentages do not describe an isolated membrane test or measurements of AURORA or BlueVital. Go to the study source ↓
Our selection from Table 1 of the study. “>” means “more than”: The bar shows the reported lower bound; actual reduction may be higher. The different households do not allow a direct ranking of appliances. A rounded value of 100% does not prove absolute absence of a substance. n = number of samples in the filter group. The jug, refrigerator and under-sink filters shown here use activated carbon. The original study also includes two-stage under-sink filters with very good results.
Keeping shorter molecules in view, too.
Activated carbon adsorbs substances on its surface. Shorter-chain PFAS are often adsorbed less effectively. High-pressure membranes such as reverse osmosis can also significantly reduce many of these substances. Technical background ↗
The complete system counts.
The reverse osmosis group figures refer to water before and after the complete system. The effects of any pre-filters are included. The membrane was not tested in isolation. The researchers' interpretation ↗
View measurements for the selected filter groups
Selection from Table 1 of the study; the measurement values shown are unchanged. The regions were evaluated separately. Find further filter groups in the original study. Scroll tables sideways on smaller screens.
| PFAS | Tap-mounted filtern = 2 | Filter jugsn = 13 | Refrigerator filtern = 22 | Activated carbon block · under sinkn = 5 | Whole-house filter · GACn = 6 | Complete RO system with pre-filtersn = 11 |
|---|---|---|---|---|---|---|
| PFBS | 94 % | 65 % | 29 % | >84 % | 18 % | 94 % |
| PFHxS | 88 % | 54 % | 65 % | >84 % | 32 % | >96 % |
| PFOS | 99 % | 71 % | 61 % | >99 % | 67 % | 100 % |
| PFBA | 63 % | 36 % | 45 % | 15 % | –34 % | >98 % |
| PFPA | 67 % | 42 % | 35 % | 52 % | –85 % | >99 % |
| PFHxA | 79 % | 43 % | 59 % | 53 % | –63 % | 98 % |
| PFHpA | 75 % | 43 % | 65 % | 52 % | –37 % | 98 % |
| PFOA | 84 % | 67 % | 71 % | 56 % | 19 % | >92 % |
| PFNA | 92 % | >54 % | 72 % | 45 % | 28 % | >88 % |
| PFDA | 99 % | >57 % | 57 % | 64 % | 44 % | >93 % |
| GenX | 63 % | 46 % | 56 % | 51 % | 21 % | >99 % |
| PFAS | Countertop filtern = 1 | Refrigerator filtern = 3 | Activated carbon block · under sinkn = 5 | Whole-house filter · GACn = 2 | Whole-house filter · GAC/CIXn = 5 | Complete RO system with pre-filtersn = 7 |
|---|---|---|---|---|---|---|
| GenX | –146 % | >78 % | >74 % | 55 % | –7 % | >75 % |
| PFMOAA | –498 % | 92 % | 91 % | 40 % | –106 % | 97 % |
| PFO2HxA | –284 % | 98 % | 94 % | 54 % | 58 % | 97 % |
| PFO3OA | 11 % | >99 % | 97 % | 64 % | 60 % | >99 % |
| PFO4DA | 70 % | 99 % | 99 % | 63 % | 69 % | 99 % |
| Nafion BP2 | 55 % | 97 % | >99 % | 52 % | 1 % | 99 % |
Negative values: higher concentration after filtration. GAC = granular activated carbon; GAC/CIX = combination with ion exchange. For the southeastern ether PFAS, the evaluation is based on internally standardised measurement signals. The reverse osmosis GenX value “>75%” is limited by the detection limit: GenX was not detectable in the filtered water.
REDUCE EXPOSURE WHERE YOU CAN
Your daily water
is a place to start.
Water for drinking and cooking can be treated at the point of use. A reverse osmosis system separates many dissolved substances from the treated water; a separate stream carries the retained substances away. PFAS are separated, not destroyed. Installation and regular maintenance also matter. Technology background ↗
AURORA combines pre-filtration and reverse osmosis. We discuss how the system fits your water, your everyday life and your budget.
Understand how the filters work together →What this study tells us about our appliances: It supports the choice of reverse osmosis as a filtration method. AURORA and BlueVital were not tested. The percentages are not a performance promise for our appliances. TFA was not included in this study.
How was the study conducted – and what remains open?
73 households, samples from 2017–2019 and various filters already in use. Small groups and some repeated measurements limit how widely the results can be applied. Group averages do not show a guaranteed minimum performance for every filter. The study examined neither all PFAS nor disease prevention.
For a specific system, measurements before and after filtration under documented conditions are informative. Source water, individual substances tested, detection limits and time in use are part of the result. An analysis from your local water supplier is a good starting point for advice.
Go directly to the research
Herkert, N. J. et al. (2020): Assessing the Effectiveness of Point-of-Use Residential Drinking Water Filters for Perfluoroalkyl Substances (PFASs). Environmental Science & Technology Letters, 7(3), 178–184. DOI: 10.1021/acs.estlett.0c00004. Chart and table data: Table 1; context: results and discussion.
US EPA: Reducing PFAS in Drinking Water with Treatment Technologies. Technical explanation of activated carbon, ion exchange and high-pressure membranes.
Our own charts based on published figures; not reproductions of the original ACS figure. Added on 1 November 2026; translated into English.
Your water. A considered decision.
Bring your questions and, if available, your water report.

Swiss drinking water.
A good starting point.
The Federal Food Safety and Veterinary Office generally assesses drinking water in Switzerland as good. Water suppliers test it regularly; cantonal laboratories oversee the supply.
Well monitored does not mean free of contaminants. Even when limits are met, small amounts of unwanted substances may be present. Legal maximum levels protect health. They are not, however, recommendations for what your body should take in. For us, this also raises the question of how unwanted residues in water can be reduced further in a targeted way.
For your own situation, your water supplier's report and, where appropriate, a targeted analysis at your tap are more informative than general claims.
FSVO: drinking water quality and monitoring · Residues and maximum levels
YOUR QUESTIONS ABOUT WATER
Take a closer look.
Does every household need a water filter?
That depends on your water and what matters to you personally. Would you like to reduce specific unwanted substances, change the taste or treat water for coffee, tea and cooking? Start with your wishes and what you want additional treatment to achieve.
Then look at your source water and household plumbing. Your water supplier's report and, for specific questions, a targeted water analysis help put things in context. Together, we can clarify whether treatment suits your aims, which type is appropriate and what effects it can demonstrably achieve. You can then make your own informed decision.
What about PFAS, TFA, nitrate or microplastics?
Fewer unwanted substances in water – that is our aim. That is why AURORA combines activated carbon with reverse osmosis. Even where limits are met, you can make a conscious choice to use additional treatment.
Reverse osmosis can reduce various PFAS, including TFA, and nitrate, and retain microplastics. Studies using different reverse osmosis membranes and systems show this. Find the studies on PFAS [4], TFA [5], Nitrate [6] and Microplastics [7].
The degree of reduction depends on the substance, membrane, source water and operating conditions. If certain substances matter particularly to you, we will review your water report with you and discuss treatment that fits your needs.
Why remove unwanted substances from drinking water before drinking it?
What we remove from water before drinking it is no longer taken in through that water. That is the focus of our water treatment: reducing unwanted substances before they enter the body.
Lower intake can help reduce the burden of certain substances over time. The effect depends on the substance, other exposure sources and how it is eliminated. Our aim is therefore to minimise avoidable intake through drinking water. [1]
What can activated carbon and reverse osmosis do about PFOA?
In the study by Bartell and colleagues (2010), blood PFOA levels fell after activated carbon filtration was introduced in two heavily contaminated water supplies. The study shows that reducing intake through drinking water can make a difference. [1]
At the Rauental waterworks, 25 tonnes of activated carbon removed around 516 grams of PFAS from the water in the first year of operation. Source: Stadtwerke Rastatt, PFAS chronology, January 2025, page 10 (PDF, German).
A good reverse osmosis system can achieve more PFAS reduction than a simple activated carbon filter. Study of household filters: Herkert and colleagues (2020) · View measurements and charts ↓. Reverse osmosis can effectively reduce PFOA and other PFAS in drinking water – and therefore lower intake through water. [2]
If this sustainably reduces total PFOA intake, the amount in the blood can decline over time. This is the understandable connection between water treatment and blood levels: less new intake. How much and how quickly blood levels change also depends on other exposure sources and individual elimination. [3]
AURORA combines activated carbon and reverse osmosis. The blood study examined activated carbon filtration; the cited sources are not appliance-specific evidence of rejection rates or a reduction in blood levels caused by AURORA.
What do we mean by “structuring” water?
This concerns personal perception of water – not purification. We associate “structuring” with the idea of water as close to nature as possible. We place crystal and Bovis information within this understanding too. It is intended for people who consciously pay attention to how water feels to them.
Removing unwanted substances is the task of filtration. Crystal and Bovis values are not measurements of purity or filtration performance. How you experience water is your personal perception.
Sources for further reading
- FSVO: Swiss drinking water
- [1] Bartell and colleagues (2010): declining blood PFOA levels after activated carbon filtration (English)
- [2] US EPA: PFAS reduction using activated carbon and reverse osmosis (English)
- [3] ATSDR: blood levels after reduced PFAS intake through drinking water (English)
- US health institute NIDDK: kidney function (English)
- [4] Safulko and colleagues (2023): PFAS rejection by nanofiltration and reverse osmosis (English)
- [5] Scheurer and colleagues (2017): TFA in the water cycle and removal methods (English)
- [6] Aquademia (2020): influence of operating conditions on nitrate reduction by membranes (English)
- [7] Taligrot and colleagues (2025): retention of microplastics by reverse osmosis membranes (English)
UNDERSTAND YOUR WATER BETTER
One report.
The right questions.
Whether you want to refine the taste of your coffee or reduce specific residues, your aims set the direction. An up-to-date water report helps you choose suitable treatment.
Limit, measurement, study finding – what is the difference?
A legal maximum level describes a binding requirement. A measurement shows what was found in a particular sample. A study finding describes the result of an investigation under its particular conditions. These kinds of information answer different questions.
Scientific risk assessment and setting binding rules are different tasks. EFSA: risk assessment and risk management.
“Not detectable” does not automatically mean “not present”. The detection limit describes the point at which a method can detect a substance; the quantification limit is the point at which its amount can be determined with sufficient accuracy. Definitions: Annex 5, section 1.3 of the German Groundwater Ordinance – used here to explain measurement terms, not as a Swiss drinking water rule.
What should I bring to a water consultation?
- Your water supplier's current report, including its date, the substances tested and the results.
- Your wishes: taste, specific residues, water for enjoyment or for the whole family.
- An idea of your daily consumption – including coffee, tea, cooking and refillable bottles.
- If possible, a photo of the space under your sink. This helps us plan installation and equipment with you.
We look together at what matters to you and clarify suitable technology, maintenance and costs.
Discuss your water with us →For anyone who wants to look more closely.
At BlueVital, our brand for everyday family life, you will find more detailed information on PFAS, nitrate, microplastics and nanoplastics – with studies, original sources and context for families.
Water insights for families at BlueVital (German) →Energisation & personal perception of water
Your water. Your perception.
For people who also want to experience water consciously: the Bovis scale provides a radiesthetic interpretation. Here is an overview of the values stated for our energisation options.
Bovis values at a glance
Traditional ranges and extended scale
| Range in Bovis | Radiesthetic interpretation¹ | Energisation · stated values² |
|---|---|---|
| Range in BovisBelow 6,500 | Low vitality | Traditional reference range |
| Range in Bovis6’500 – 8’000 | Neutral to vital | Traditional reference range |
| Range in Bovis8’000 – 20’000 | High vitality | Traditional reference range |
| Range in Bovis20’000 – 100’000 | Very high energetic value | Comparison system using water swirling and semi-precious stonesAmethyst, rock crystal and rose quartzapprox. 24’000Bovis² |
| Range in Bovis100,000 – 1 million | Extended scale range | BlueVitalEnergisationapprox. 250’000Bovis |
| Range in Bovis1 – 10 million | Extended scale range | AQUA HELVETICAEnergisationup to approx. 9.5 million9,500,000 Bovis |
Places that fascinate people.
Four well-known places with published Bovis attributions.³
Great Pyramid of Giza
Interior · Egypt
approx. 170’000Bovis · value stated by source³Stonehenge
Stone circle · England
approx. 2.2 millionBovis · value stated by source³Chartres Cathedral
Centre of the labyrinth · France
up to approx. 4 millionBovis · value stated by source³Machu Picchu
Inca site · Peru
approx. 4.5 millionBovis · value stated by source³³ Place values according to NHA Naturolistique, section on Bovis values of places. Values can vary considerably by source, exact location and method. These are radiesthetic attributions, not verified measurements of places or a direct performance comparison with water products.
Personal perception and water purification are two different subjects. Bovis values belong to radiesthesia and are not scientifically standardised measurements of energy, purity, filtration performance or health effects. How water feels to you remains your personal perception.
¹ Traditional interpretations according to Phipower: Bovis values of vitalised water; they may vary according to the radiesthetic method. The ranges from 100,000 have been extended to 10 million for this overview. Row heights do not represent proportional intervals.
² Values for the comparison system, BlueVital and AQUA HELVETICA are based on information from AQUA HELVETICA and have not been independently verified. The 24,000 Bovis figure refers to the comparison system described and is not a universal standard value. The linked source explains the scale but does not substantiate these product values.
DISTINCTLY SWISS – ALWAYS PERSONAL
Your water. Your questions.
Bring your questions and, if available, your water supplier's report to the consultation.
Request a demonstration