THOUGHTFUL TECHNOLOGY

Two stages.
Many capabilities.

Good technology lies in how the parts work together. AURORA combines the right functions in two carefully matched filter stages. For demanding water treatment that stays simple in everyday use.

FILTER TECHNOLOGIES COMPARED

What can each technology do?

Compare the methods – and the combination of sediment filtration, activated carbon and reverse osmosis in AURORA and BlueVital.

AURORA and BlueVital combine sediment filtration, activated carbon and reverse osmosis. Their shared column represents how these components work together – and AQUA HELVETICA's qualitative assessment.

Qualitative assessment by AQUA HELVETICA. The terms describe an assessment of reduction performance; they are not percentages.

On smaller screens, scroll sideways to see the full table.

Treatment technologies, AURORA and BlueVital · qualitative assessment by AQUA HELVETICA
Substances
in water
AURORA
and BlueVitalSystems by AQUA HELVETICA
IonisationNO PURIFICATIONFilter jugsActivated carbonGranular carbon (GAC)Activated carbonblock filterDistillationReverse osmosisSystem with pre-filtration
LimescaleVERY HIGHNOLIMITEDNONOHIGHVERY HIGH
BacteriaVERY HIGHNOLIMITEDLIMITEDLIMITED *VERY HIGHVERY HIGH
Heavy metalsVERY HIGHNOLIMITEDLIMITEDLIMITEDVERY HIGHVERY HIGH
ChlorineVERY HIGHNOHIGHVERY HIGHVERY HIGHLIMITEDVERY HIGH
PesticidesVERY HIGHNOLIMITEDHIGHVERY HIGHHIGHVERY HIGH
Pharmaceutical residuesVERY HIGHNONOLIMITEDHIGHLIMITEDVERY HIGH
Organic compoundsVERY HIGHNOHIGHHIGHVERY HIGHLIMITEDVERY HIGH
AsbestosVERY HIGHNONONOHIGHVERY HIGHVERY HIGH
PFASVERY HIGHNOPARTLYLIMITEDLIMITEDHIGHVERY HIGH
TFAVERY HIGH†NONONOLIMITEDHIGHHIGH
Microplastics (> 1 µm)VERY HIGHNOLIMITEDPARTLYHIGHHIGHVERY HIGH
Nanoplastics (< 1 µm)VERY HIGH†NONOLIMITEDPARTLYLIMITEDHIGH
Nitrate & nitriteVERY HIGHNONONONOHIGHVERY HIGH
VOCs (solvents)VERY HIGHNOLIMITEDVERY HIGHVERY HIGHLIMITEDHIGH
Filtering PFAS: what do measurements show?Reverse osmosis, activated carbon and filter jugs – study results in clear charts. →

The ratings come from the AQUA HELVETICA comparison table. Actual reduction depends on the individual substance, the components, their capacity and operating conditions. “Very high” does not mean complete removal of every substance in a group.

† The ratings for TFA and nanoplastics reflect AQUA HELVETICA's qualitative assessment. They are not based here on published test reports for these specific appliances.

DISTINCTLY SWISS – THOUGHTFULLY DESIGNED

AURORA.
Working together makes the difference.

High-quality activated carbon and sediment filtration provide pre-treatment. The reverse osmosis membrane adds the reduction of numerous dissolved substances. AURORA brings the strengths of both methods together in two carefully matched filter stages.

Activated carbon reduces free chlorine, for example, and adsorbs many organic compounds. The membrane performs further tasks. What matters is the complete system – from the pre-filter and pump to the membrane.

Discover how AURORA's technology works together →
Context and sources for the comparison

Basis of the table: the “Reinigungstechnologien V2” overview supplied by AQUA HELVETICA. Its qualitative ratings are presented here as the supplier's assessment, not as independent comparative measurements.

  • Reverse osmosis and pre-filtration: The reverse osmosis information refers to a system with suitable pre-filtration. In particular, chlorine reduction is achieved through pre-treatment, usually activated carbon; it is not a function of the reverse osmosis membrane alone.
  • The shared column for AURORA and BlueVital describes the combination of sediment filtration, activated carbon and reverse osmosis. Both systems use this technological principle; their components and features differ. An assessment of the overall system must be distinguished from an assessment of a single method.
  • * Bacteria and activated carbon block filters: Retention depends on pore size and the specific filter design. The hygiene of the complete installation also depends on use and maintenance.
  • Substance groups and filter types include different variants. For example, some filter jugs with suitable media can also reduce certain PFAS. “PARTLY” describes a reduction that depends on the substance and filter; it does not replace testing of the specific product. Within the PFAS group, PFOA, PFOS and TFA behave differently.

Further background on the methods and substance-specific testing:

These sources explain the methods. They do not confirm every table rating or constitute certification of AURORA or BlueVital.

DISTINCTLY SWISS – DISTINCTLY EFFICIENT

Simplicity takes
engineering.

One pre-filter handles sediment and activated carbon filtration. The reverse osmosis membrane follows. Several tasks become two filter stages – with fewer individual cartridges for you to keep track of and replace.

A long row of filter stages alone says little about quality. What matters is the components, how they work together and their performance under the relevant operating conditions. That is where we set our standards.

01 / COMBINES THE PRE-TREATMENT

Activated carbon.
With sediment filtration.

One filter, two tasks: it retains particles and adsorbs certain dissolved substances on the surface of the activated carbon. This combination provides pre-filtration before the membrane – compact and thoughtfully designed.

Which substances are reduced, and by how much, depends on the filter and operating conditions.

02 / THE HEART OF THE TREATMENT

The reverse osmosis
membrane.

Precision at work: the pump pushes water through a semi-permeable membrane that retains numerous dissolved substances. The treated water reaches your tap; retained substances are carried away in the concentrate stream.

FROM VISIBLE PARTICLES TO DISSOLVED SUBSTANCES

How fine is
the filtration?

Some filters retain particles. Others also address dissolved substances. The graphic makes the difference visible.

From microfiltration to reverse osmosis, separation extends to progressively smaller components. These are four classes of process – not four additional filter stages in AURORA.

On smaller screens, scroll sideways to view the graphic.

Schematic filtration graphic: from left to right, larger suspended particles are retained first, then finer particles and finally dissolved substances. The four process classes are explained in the text below.

Substance groups illustrated

  • Zooplankton · algae · turbidity · bacteria · suspended particles
  • Macromolecules · viruses · colloids
  • Organic compounds · predominantly divalent ions
  • In addition to nanofiltration: monovalent ions
Schematic guide based on the AQUA HELVETICA graphic. Symbols represent substance groups; they show neither fixed size ratios nor complete removal of all substances depicted. Open the original graphic (German) ↗

Where each method works

Sediment filterSand, rust and larger suspended particles
Ceramic / microfilterParticles; bacteria depending on filter fineness
UltrafiltrationFine particles; dissolved salts largely remain
Waterworks using ultrafiltrationExample of a municipal membrane stage · up to UF

Ultrafiltration retains bacteria and parasites; virus retention depends on the membrane. Small dissolved substances such as nitrate and many salts largely pass through it. Reverse osmosis goes a step further for many of these dissolved substances.

One example is the Männedorf lake water treatment plant, where ozonation, activated carbon and ultrafiltration work together.

How do Swiss waterworks treat their water?

The aim is hygienically safe drinking water. The methods used depend on the source water and the plant. Some spring water and groundwater needs no additional treatment. Other plants use, for example, disinfection, sand and activated carbon filters or membranes. This is explained by the Swiss professional association SVGW.

Some plants also use reverse osmosis, such as the new Ipsach lake water treatment plant. The bar above therefore shows an ultrafiltration stage as an example, not a universal filtration limit for all Swiss waterworks.

Activated carbonAdsorbs selected substances – including dissolved ones
ChlorineOdour- and taste-causing substancesMany organic compounds

A carbon block can also retain particles. Its fineness and its ability to adsorb dissolved substances are two different properties.

And simple filter jugs or tap filters?

The housing alone tells you nothing about filtration performance. Many contain activated carbon, sometimes combined with ion exchangers. Depending on the cartridge, the focus is on taste, chlorine or limescale. Further retention performance depends on the media used.

AURORA and BlueVitalSediment filtration + activated carbon + reverse osmosis

Together, they extend treatment to many small dissolved substances and ions, such as nitrate.

Bars show schematic areas of application, not fixed size limits or complete removal. The effect depends on the substance, filter design and operation.

Background to the assessment
EPA · activated carbon and membrane processesCDC · microfiltration, ultrafiltration, nanofiltration and reverse osmosisNSF · substance-specific filter performance

Background on the methods; not measurements for specific appliances.

MF

Microfiltration

Indicative value: approx. 0.1 µm

Retains larger suspended particles, algae and many substances causing turbidity. Whether bacteria are also retained depends on pore size.

Dissolved salts and very small dissolved substances largely pass through the membrane.

UF

Ultrafiltration

Indicative value: approx. 0.01 µm

Also captures finer particles, colloids, large molecules and bacteria. Virus retention depends on the membrane.

Dissolved mineral salts largely remain in the water.

NF

Nanofiltration

Indicative value: approx. 0.001 µm

Reaches many dissolved organic compounds and preferentially retains multivalent ions, such as calcium and magnesium.

Small monovalent ions such as sodium and chloride are retained less strongly, depending on the membrane.

RO

Reverse osmosis

Separation down to dissolved ions

Also reduces numerous small dissolved substances and monovalent ions. These include sodium, chloride and nitrate, for example.

This membrane process is used in AURORA. The upstream activated carbon stage adds further functions.

How small is that? 1 µm (micrometre) is one thousandth of a millimetre. 0.001 µm equals 1 nm (nanometre).

Size is not everything. The figures are guides, not fixed limits. Charge and membrane material also play a role, particularly in nanofiltration and reverse osmosis. The dense separation layer in reverse osmosis cannot be described like an ordinary sieve with a fixed pore size.

Background: CDC: membrane processes · DuPont: ultrafiltration · Nanofiltration · Reverse osmosis (in English).

Which technology suits which substances? See the comparison →

THOUGHTFUL DESIGN PAYS OFF EVERY DAY

Fewer parts to replace.
More in your own hands.

Focused on the essentials

Combining several functions in one filter means there is no need to buy and replace separate cartridges for each. This keeps maintenance manageable and cost-efficient.

Do it yourself

You can change the activated carbon filter and membrane yourself. This avoids technician visits, travel and labour costs for those replacements. The online membrane replacement guide is still to come; our service team can help with the procedure. You can request a technician if you wish.

Think over the years

A good purchase includes considering running costs. Compare replacement part prices, intervals and necessary service visits over the entire period of use.

Calculate your costs →

PROFESSIONAL PUMP TECHNOLOGY

Power within.
For your everyday life.

AURORA uses a FLUID-O-TECH pump head and a separate RPM electric motor. Rotating vanes move water through the pump head: this design is called rotary vane. The pump builds the pressure needed for reverse osmosis. The motor has thermal overheating protection.

The same purified water output. Less electricity. Noticeably quieter. With its carefully matched pump technology, the current AURORA delivers the same amount of purified water as its predecessor – using less energy. The new pump does not need water cooling; its specified motor power is 180 W, compared with the previous 300 W.

Your benefit: enjoy full water output, more peace in your kitchen and lower electricity use.

DISTINCTLY SWISS – FOCUSED ON YOU

The pump specifications on this website refer to current appliances. Earlier models had a water-cooled pump with a 300 W motor.

Internal water recirculation and automatic flushing complement the system. Get to know AURORA's pump technology →

The display indicates when a filter change is due. According to the supplier, the equipment includes leak sensors and a water inlet shut-off.

These functions do not replace professional installation or the required maintenance.

AURORA in a stainless steel housing with a subtly blue-lit display – product visualisation

READING MEASUREMENTS CORRECTLY

What does a number tell you?

What does 800 GPD mean?

GPD stands for US gallons per day. One US gallon is around 3.785 litres. 800 GPD therefore equals around 3,028 litres per day – about 126 litres per hour or 2.1 litres per minute.

2.1 litres per minute is not a fixed upper limit for AURORA. 800 GPD describes the membrane's nominal output under defined test conditions, particularly at a specified pressure and water temperature. Higher effective pressure at the membrane can increase purified water output beyond this nominal figure.

For the current AURORA, we specify a typical output of 160–180 litres per hour – around 2.7–3 litres per minute. The 2.1 l/min figure is therefore the converted nominal membrane rating; 2.7–3 l/min is our specified output for the complete operating system. Actual output depends on water temperature, water quality and operating pressure. It is lower with colder water. Purified water output of the current AURORA →

Why do we not give a blanket rejection rate?

A rejection rate always applies to a particular substance under particular test conditions. A general percentage describes neither every individual contaminant nor automatically the water quality in a household. A specific question requires a suitable test report for the system used.

Does a conductivity meter show all contaminants?

No. Electrical conductivity provides information about dissolved ions. It does not replace targeted testing for individual substances or a microbiological analysis. Low conductivity alone therefore does not prove comprehensive safety.

Is the treated water germ-free?

We do not make that blanket promise. Hygiene also depends on installation, maintenance, periods of non-use and the dispensing point. Follow the operating instructions and service guidance.

Basic technical information: US Environmental Protection Agency (EPA): drinking water treatment processes (English). Product information: published AURORA product page.

DISTINCTLY SWISS – ALWAYS PERSONAL

Some things you need to experience yourself.

A glass of water. A good conversation. And time for all your questions. We look forward to showing you AURORA.

Request a demonstration